Performance
- - The organizer of the performance test: OFI/AUSTRIA
- - The report below are performance test data for Hepa Filter mounted on KPLAZER.
- - Carrying out the tests
Examination period : 20 May 2021 to 23 June 2021
- - Task
Determination of Viral Filtration Efficiency according to OFI SOP 350.012 Viral Re-Aerosolization according to OFI SOP 350.013
Determination of Bacterial Filtration Efficiency according to OFI SOP 350.014
RESULT
Determination of viral filtration efficiency
Measurement |
Viral Filtration Efficiency[%] |
single experiments |
mean |
std. dev. |
1 |
99.98% |
99.96% |
0.02% |
2 |
99.95% |
3 |
99.95% |
Determination of bacterial filtration efficiency
Measurement |
Viral Filtration Efficiency[%] |
single experiments |
mean |
std. dev. |
1 |
99.62% |
99.71% |
0.11% |
2 |
99.67% |
3 |
99.83% |
- - The organizer of the performance test : ISEGA/GERMANY
- - The report below are performance test data for Hepa Filter mounted on KPLAZER.
- - Carrying out the Tests
Examination period : 10 January 2018 to 2 February 2018
- - Test of Antimicrobial Efficacy
- - The test was performed in analogy to the method AATCC TM100:2012.
- - After application of 0.25ml germ suspension(dilution in 0.9% NaCl-solution) per specimen(2x2cm)
- - The specimens were stored individually in sterile petri dishes at 36°C.
- - At the end of the contact the germs were dissolved in 10ml BD D/E neutralization broth and the number of bacteria was determined by plate count method.
- - An additional sterilization of the sample material was not performed.
- - The examination was performed as threefold determination.
- - Test germ: Staphylococcus aureus(DSM 799), Escherichia coli(DSM 1576)
- - Contact points : 0 h and 24 h
- - Contact temperature : 36°C.
- - Nutrient medium : CASO-agar
- - Incubation : 2 days
Result - Escherichia coli
initial colony count t0 [CFU(log10 CFU)] |
initial colony count t24 [CFU(log10 CFU)] |
%-reduction |
8.9 × 10⁴(4.95) |
< 10(1.00) |
> 99.99 ± 0.00 |
Result - Staphylococcus aureus
initial colony count t0 [CFU(log10 CFU)] |
initial colony count t24 [CFU(log10 CFU)] |
%-reduction |
1.6 × 10⁴(4.17) |
< 10(1.00) |
> 99.98 ± 0.00 |
-
- The organizer of the performance test : KTL/KOREA
- - The following data are performance test data for KPLAZER.
- - Carrying out the Tests
Examination period : 04 May 2021 to 05 May 2021
- - Test Standard / Method of : KOUVA AS 02:2019
- - Test germ(A) : Phi-X174(ATCC 13706-B1)
- - Test germ(B) : S.epidermidis(ATCC 12228)
Test Results(A) :
Unit & Results |
Airborne Virus reduction rate |
Air disinfectant device |
97% |
Test Results(B) :
Unit & Results |
Airborne Virus reduction rate |
Air disinfectant device |
99% |